TN-73 High-precision VU Meter DB Power Discharge Flat Meter Mixer Power Meter

Description

Specification
1. Movable part: movable coil type
2. Pointer materials: Nickel Silver Strips
3. Pointer color: Black
4. Direction of pointer swing: From left to right
5. Pointer length: 30+/-1mm from the center axis to the end of the needle
6. Pointer width: 0.45 +/- 0.05mm
7. Direction of use: Vertical
8. Operating temperature limit: -10 degree C to + 60 degree C RH 35 to 85%
9. Storage temperature limit: -20 degree C to + 60 degree C RH 35 to 85%
10. Solder condition: Put the terminal about 3 mm into a tin plate with a temperature of 230 degree C. The placement time is 3.5 seconds. After this test, 7-14 items remain normal.
11. Solder temperature: hold the solder gun at 350a?? for 3.5 seconds, and the front end of the terminal is about 3mm in contact with the solder gun. After this test, items 7-14 remain normal.
12. Anti-static: use dry nylon cloth to test the transparent cover surface in the same direction for three times. Mark the pointer difference below 1/3 of the scale length, and return to zero after three seconds.
13. Light bulb specification: DC12V 12W

Note: Do not put the meter in direct sunlight, and store the meter in the packing box to prevent foreign matter from entering the meter

Electrical Performance
1. Standard test conditions: temperature 20 degree C, humidity 70%, no difference in test results, it can also be tested under normal temperature and humidity.
2. Electric influenza degree: Pointer sensitivity 1mA+/- 5% from zero scale to uppper scale (full scale position)
3. Internal impedance: 50ohm+/- 5%
4. Insulation impedance: above 500V DC plus 50M OHm for the charging circuit of the meter outer box. Insulation impedance between the casing of the meter and the charging circuit is tested at 500V DC voltage.
5. Zero position: the meter is in a standard position. The place where the front end of the pointer is integrated with the zero scale center is the reference. The permissible error of the overlap between the pointer and the zero scale is +/-1mm.
6. Equalization: Permissible error range ??±1mm when the standard position of the meter is tilted 90 degrees before and after use.
7. Stick pointer: instantly add three times the full scale current over current, slowly reduce to 1/2 of the electric flu reading, then the pointer will return to 1/3 of the scale.
8. Friction: The error range of indicating point ??±1mm when the electric current is added to the meter and slowly increased or decreased to a certain value.
9. Braking: Instantly add 2/3 of the current of the dial plate, within one second from the beginning to the position indicated by the pointer.

Special Test
1. Over load test: input ten times the full scale current every five seconds, repeat this action for nine times. Each time is 0.5 seconds, 7 to 14 items remain normal after this test.
2. Vibration test: After the meter is packaged, it is shaken up and down by 4mm every 1,000 times per minute on the vibration plate, 10 minutes in each direction. After this test, 7-14 items remain normal.
3. Impact test: The meter fell from a height of 30cm to a 3cm thick board after being packaged, and the test was conducted in three directions,X.Y.Z, 7-14 items remained normal after this test.
4. Reliability test: Electrofluence limit remains within standard after 100,000 correction point current inputs.
5. Environmental impact test: Temperature 50a??, humidity 85%, lasting 100 hours, after this test 7-14 items remain normal.
6. Terminal tension test: the terminal must bear 1 kg tension, lasting for 60 seconds.

TN-73 High-precision VU Meter DB Power Discharge Flat Meter Mixer Power Meter

Product form

SKU: HC5705

  • In stock (Processing Time 1 - 72 hours)

€22,38

    • Guaranteed secure & safe checkout.

    Icon for truckShipping Methods

    To find out all available shipping methods, and the exact delivery time add the product to the cart and verify it using our shipping calculator.

    Icon for 24_hour_clockOrder Processing Time

    All orders are shipped within a maximum of 72 hours from the order's arrival.

    Icon for coinMoney Back Guarantee

    Garmade Money Back Guarantee- Get the item you ordered or your money back, it's that simple.

    Icon for image_placeholderMismatched Product

    Product doesn't match the description? Contact us within 31 days after you receive it!

    Icon for mobile_paymentRefunds

    In case of cancellation, money will be refunded to your account within 14 days.

    Description

    Specification
    1. Movable part: movable coil type
    2. Pointer materials: Nickel Silver Strips
    3. Pointer color: Black
    4. Direction of pointer swing: From left to right
    5. Pointer length: 30+/-1mm from the center axis to the end of the needle
    6. Pointer width: 0.45 +/- 0.05mm
    7. Direction of use: Vertical
    8. Operating temperature limit: -10 degree C to + 60 degree C RH 35 to 85%
    9. Storage temperature limit: -20 degree C to + 60 degree C RH 35 to 85%
    10. Solder condition: Put the terminal about 3 mm into a tin plate with a temperature of 230 degree C. The placement time is 3.5 seconds. After this test, 7-14 items remain normal.
    11. Solder temperature: hold the solder gun at 350a?? for 3.5 seconds, and the front end of the terminal is about 3mm in contact with the solder gun. After this test, items 7-14 remain normal.
    12. Anti-static: use dry nylon cloth to test the transparent cover surface in the same direction for three times. Mark the pointer difference below 1/3 of the scale length, and return to zero after three seconds.
    13. Light bulb specification: DC12V 12W

    Note: Do not put the meter in direct sunlight, and store the meter in the packing box to prevent foreign matter from entering the meter

    Electrical Performance
    1. Standard test conditions: temperature 20 degree C, humidity 70%, no difference in test results, it can also be tested under normal temperature and humidity.
    2. Electric influenza degree: Pointer sensitivity 1mA+/- 5% from zero scale to uppper scale (full scale position)
    3. Internal impedance: 50ohm+/- 5%
    4. Insulation impedance: above 500V DC plus 50M OHm for the charging circuit of the meter outer box. Insulation impedance between the casing of the meter and the charging circuit is tested at 500V DC voltage.
    5. Zero position: the meter is in a standard position. The place where the front end of the pointer is integrated with the zero scale center is the reference. The permissible error of the overlap between the pointer and the zero scale is +/-1mm.
    6. Equalization: Permissible error range ??±1mm when the standard position of the meter is tilted 90 degrees before and after use.
    7. Stick pointer: instantly add three times the full scale current over current, slowly reduce to 1/2 of the electric flu reading, then the pointer will return to 1/3 of the scale.
    8. Friction: The error range of indicating point ??±1mm when the electric current is added to the meter and slowly increased or decreased to a certain value.
    9. Braking: Instantly add 2/3 of the current of the dial plate, within one second from the beginning to the position indicated by the pointer.

    Special Test
    1. Over load test: input ten times the full scale current every five seconds, repeat this action for nine times. Each time is 0.5 seconds, 7 to 14 items remain normal after this test.
    2. Vibration test: After the meter is packaged, it is shaken up and down by 4mm every 1,000 times per minute on the vibration plate, 10 minutes in each direction. After this test, 7-14 items remain normal.
    3. Impact test: The meter fell from a height of 30cm to a 3cm thick board after being packaged, and the test was conducted in three directions,X.Y.Z, 7-14 items remained normal after this test.
    4. Reliability test: Electrofluence limit remains within standard after 100,000 correction point current inputs.
    5. Environmental impact test: Temperature 50a??, humidity 85%, lasting 100 hours, after this test 7-14 items remain normal.
    6. Terminal tension test: the terminal must bear 1 kg tension, lasting for 60 seconds.

    Additional Information

    Icon for truckShipping Info

    IMPORTANT INFO - PLEASE CHECK BEFORE ORDERING.



      Estimated transit time and postage fee depends on the method you choose at checkout. Please add the desired product to the cart and there you will be able to see all this information.

      Complete and right address is the guarantee of fast and efficient delivery, so please kindly recheck it when you place an order.

      In order to ensure a fast and efficient delivery, we need to have the method of contact with you. Email and Phone Number is a very important detail and must be accurate. All orders with an incorrect email or phone number will be canceled immediately.

      We strive to dispatch all orders within 72 hours of placing your order. But sometimes if the order is big or the products are more sophisticated, it can take a little longer. As soon as we dispatched it, you will receive a confirmation email along with a tracking number.

      Please be aware that sometimes due to unclear address, hard to access, no answer at address, the package can be kept at your local post office for collection. In this case you will be informed by the delivery company and by us. Please also monitor the tracking number.

      For European Union Countries:
    - If your order is less than 150€ excluding shipping costs, then the Taxes are already included in the price. This means that there will be NO extra charge upon delivery.
    - If your order is more than 150€, you will NOT be charged Taxes at the checkout, and you will have to pay upon delivery based on your local VAT rate.

     

    Icon for reviewReviews

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    Login

    Forgot your password?

    Don't have an account yet?
    Create account